Hazardous Environment Installation Instructions - R920 - 354-100000Bv1/Hazardous-Environment-Installation-Instructions

R980 Ruggedized Router Quick Start Guide for Hazardous Locations

ft:locale
en-US
ft:sourceName
Paligo_Prod

Installation Instructions are provided with each device and shall include the following in addition to ordinary locations marking under File E467298-A6020-UL, Issued 2022-10-20.

  • This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D OR non-hazardous locations only.  

  • This device is open-type device to be installed in a tool only accessible enclosure suitable for the environment.  

  • Warning

    “WARNING – EXPLOSION HAZARD. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS FREE OF IGNITABLE CONCENTRATIONS.”  

  • Antennas intended for use in Class I, Division 2 Hazardous Locations must be installed within the end use enclosure.  

  • Ambient temperature range: -30°C to +70°C (without adapter).

  • Temperature Code T4  

  • Altitude up to 2000 m (or 80 kPa).  

  • The device is not permitted to use with power adapter in hazardous locations.

  • When the required instructional material is provided by electronic media, the required instructional material shall be available in printed format upon request of the user.