Installation Instructions are provided with each device and shall include the following in addition to ordinary locations marking under File E467298-A6020-UL, Issued 2022-10-20.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D OR non-hazardous locations only.
This device is open-type device to be installed in a tool only accessible enclosure suitable for the environment.
Warning
“WARNING – EXPLOSION HAZARD. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS FREE OF IGNITABLE CONCENTRATIONS.”
Antennas intended for use in Class I, Division 2 Hazardous Locations must be installed within the end use enclosure.
Ambient temperature range: -30°C to +70°C (without adapter).
Temperature Code T4
Altitude up to 2000 m (or 80 kPa).
The device is not permitted to use with power adapter in hazardous locations.
When the required instructional material is provided by electronic media, the required instructional material shall be available in printed format upon request of the user.