Perform the following steps based on the desired connectivity.

Ethernet/PoE

If you are using a wired Ethernet connection, connect the Ethernet cable to the 0PoE port on the router. To use power over Ethernet (PoE), connect the cable's other end to a PoE-enabled network source or an IEEE 802.3af compatible PoE injector. All Ethernet ports default to LAN except in the case of a USB-to-Ethernet Adapter, which defaults to WAN.

Note

When using PoE to power the router, both data and power are sent over the same Ethernet cable.

E__S400_Ethernet_PoE_port_highlighted.png

When using PoE, the router will automatically power up. Allow a short time for the router to run through the bootup sequence. Once powered up, you can activate the router using NetCloud Manager.

If you have installed the Ethernet Expansion Module (MC20-ETH), connect Ethernet cables as needed:

E__S400_Series_RJ45_module_ports_highlighted.png

DC Power and GPIO Port

  1. If you are not using PoE power, connect the power supply plug to the DC power port on the router and then plug the other end into an electrical outlet.

  2. The router will automatically power up. Allow a short time for the router to run through the bootup sequence. Once powered up, you can activate the router using NetCloud Manager.

The 4-pin DC power/GPIO cable socket is configured to allow for using a 4-wire power/GPIO cable to hardwire power for DC connections, or for using GPIO. Refer to the following for pin configuration when making a custom cable. The recommended connector is a 4-pin 2x2 Molex micro-fit.

4pin_socket.png

Pin

Name

NetCloud Manager Name

Description

Optional GPIO Cable Colors

1

Ground

Ground

Black

2

Power

9-33 VDC (>13 W)

Red

3

GPIO_1

(GPIO) 1 on power cable

  • LVTTL Input

  • LVTTL Output

  • Open Drain (500 mA sink, 33 VDC max.)

Orange

4

GPIO_2

(GPIO) 2 on power cable

  • LVTTL Input

  • LVTTL Output

  • Open Drain (500 mA sink, 33 VDC max.)

Blue

Note

The diagram shows the view looking into the socket on the router. Be sure to take this into account when building a custom cable.

GPIO Expansion Module (MC20-GPO)

Requires the GPIO Expansion Module (MC20-GPO) to be installed. The 3.3 VDC and 9-33 VDC current-limited outputs may be used to power application logic or sensors.

Note

When using the optional GPIO Cable, carefully identify the bi-color wires.

E__S400_Series_GPIO_module_pins_labeled.png

Pin

Name

NetCloud Manager Name

Description

Optional GPIO cable colors

1

Ground

Ground

Black

2

ADC CH1

ADC Channel 1

Analog Input (selectable ranges of 0-5 V and 0-36 V)

Green + White

3

ADC CH2

ADC Channel 2

Analog Input (range of 0-36 V only)

Red + White

4

Ground

Ground

Black

5

GPIO_2

(GPIO) 2 on expansion module

  • LVTTL Input and Output

  • Open Drain (500mA sink, 33 VDC max)

Green

6

GPIO_4

(GPIO) 4 on expansion module

LVTTL Input and Output

Brown

7

GPIO_6

(GPIO) 6 on expansion module

LVTTL Input and Output

Purple

8

Ground

Ground

Black

9

GPIO_8

(GPIO) 8 on expansion module

LVTTL Input and Output

Blue

10

GPIO_10

(GPIO) 10 on expansion module

LVTTL Input and Output

Yellow

11

3.3 VDC

3.3 V supply output

3.3 VDC Output (200 mA max)

Orange

12

Ground

Ground

Black

13

Ground

Ground

Black

14

9-33 VDC

9-33 V supply output

9-33 VDC Output (100 mA max, sourced from router Power input)

Red

15

GPIO_1

(GPIO) 1 on expansion module

  • LVTTL Input and Output

  • Open Drain (500mA sink, 33 VDC max)

White

16

GPIO_3

(GPIO) 3 on expansion module

LVTTL Input and Output

Pink

17

GPIO_5

(GPIO) 5 on expansion module

LVTTL Input and Output

Blue + White

18

Ground

Ground

Black

19

GPIO_7

(GPIO) 7 on expansion module

LVTTL Input and Output

Grey

20

GPIO_9

(GPIO) 9 on expansion module

LVTTL Input and Output

Orange + White

When building a custom cable for use with this expansion module, the following Molex parts are recommended for electrical and mechanical compatibility:

  • Micro-Fit connector housing: Molex 43025-2000

  • Micro-Fit Reduced Mating Force (RMF) crimp terminals:  Molex 46235-0001

For compatible GPIO cables, see below.

Optional Accessories: GPIO Cables

Mating 2x10 and 2x2 GPIO cables are available for order separately.

Optional Accessory

PART NUMBER

2x10 GPIO Expansion Module Cable

170919-000

2x2 3M GPIO & Power Cable, 20 AWG

170864-001

Serial Expansion Module

Requires the MC20-SRL Serial Expansion Module to be installed. Connect a serial cable to the Serial Expansion Module and tighten the screws on either side of the plug to secure it. When building your own serial cable, use the following table:

Socket

Pin

Function

Details

E__S400_Series_Serial_module_pins.png

1

Carrier Detector (DCD)

NC

2

Receive (Rx)

Input

3

Transmit (Tx)

Output

4

Data Terminal Ready (DTR)

Output

5

Signal Ground/Common (SG)

Ground

6

Data Set Ready (DSR)

Input

7

Request to Send (RTS)

Output

8

Clear to Send (CTS)

Input

9

Ring Indicator

NC