The following information is required for ATEX (Europe) and CID2 (North America) hazardous location installations.
Conditions of Use: CID2
Installation Instructions are provided with each device and shall include the following in addition to ordinary locations marking under File E467298-A6020-UL, Issued 2022-10-20.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D OR non-hazardous locations only.
Warning
WARNING – EXPLOSION HAZARD. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS FREE OF IGNITIBLE CONCENTRATIONS.
This device is an open-type device to be installed in a tool-only accessible enclosure suitable for the environment.
Antennas intended for use in Class I, Division 2 Hazardous Locations must be installed within the end use enclosure.
When the required instructional material is provided by electronic media, the required instructional material shall be available in printed format upon request of the user.
Detailed Environment Specifications
For safety certification requirements, these specifications apply when installing the S400 series router:
Environmental | |
|---|---|
Temperature |
|
Humidity |
|
Ingress Protection | IP30 |
Certifications | |
|---|---|
Safety |
|
Materials |
|
Shock/Vibration/Humidity |
|
Hazardous Locations | North America: Class I, Division 2, Groups A, B, C, and D Europe - ATEX: UL 24 ATEX 3274X Held by: Ericsson Enterprise Solutions, Inc 1100 W. Idaho Street Suite 800 Boise, ID 83702-5389 United States |
Regulatory |
|