General requirements:

  • Bending radius of feeder (antenna) cable: 7/8 in requires 250 mm (9.8 in) or more radius bends, 4/5 in requires a 380 mm (15 in) or more bend radius.

  • Bending radius of jumper cable: 1/4 in requires 35 mm (1.4 in) bend radius or more, 1/2 in (super soft) requires 50 mm (2 in) or more bend radius, 1/2 in (ordinary) requires 127 mm (5 in) or more bend radius.

  • Bending radius of power cable and grounding cable requires at least 3x the diameter of the cable.

  • The minimum bend radius of the optical fiber is 20x the diameter of the optical fiber.

  • Bundle the cables according to type. Do not bundle signal cables with power cables.

  • Attach an identification label to each cable as it is laid.

Grounding cable requirements:

  • The grounding cable must connect to the grounding point.

  • The grounding cable must be separate with the signal cables, with enough separation from the signal cables to avoid signal interference.