The following table lists the types of battery alerts. These include alerts for health, current and temperature, voltage and power, maintenance cycles, and backup or wall power.
Alert Category | Definition |
|---|---|
Battery Health | Creates an alert when the remaining battery life reaches 62% Example alert: Battery z3412 health is low at 62% |
Battery Over Current | Creates an alert when the battery's current reaches 3.2 amps (3200 mA) Example alert: Battery a267 is over current at 3.2 amps |
Battery Over Temperature | Creates an alert when the battery's temperature reaches 50 degrees Celsius Example alert: Battery b723 is over temperature at 50 Celsius |
Battery Over Voltage | Creates an alert when the battery's recommended voltage reaches8.5V (8500 mV) Example alert: Battery c423 is over voltage at 8.5volts |
Battery System Low Power | Creates an alert when the battery's power reaches 20% charge Example alert: Battery system is at 20% charge with 60 minutes remaining |
Battery System Power Off | Creates an alert when the battery's power reaches 7% charge Example alert: Battery system is at 7% charge with 10 minutes remaining |
Battery Maintenance Cycle Started | The battery automatically begins discharging then recharges to full power, for optimizing battery life. (E400/X20 devices) |
Battery Maintenance Cycle Ended | The battery has finished its maintenance cycle. (E400/X20 devices) |
Battery Backup Power Engaged | When an E400/X20 device loses wall power and switches over to battery backup. |
Wall Power Restored | When an E400/X20 device regains wall power and switches back from battery backup mode. |