The following table lists the types of battery alerts. These include alerts for health, current and temperature, voltage and power, maintenance cycles, and backup or wall power.

Table 1. Battery Alerts

Alert Category

Definition

Battery Health

Creates an alert when the remaining battery life reaches 62%

Example alert: Battery z3412 health is low at 62%

Battery Over Current

Creates an alert when the battery's current reaches 3.2 amps (3200 mA)

Example alert: Battery a267 is over current at 3.2 amps

Battery Over Temperature

Creates an alert when the battery's temperature reaches 50 degrees Celsius

Example alert: Battery b723 is over temperature at 50 Celsius

Battery Over Voltage

Creates an alert when the battery's recommended voltage reaches8.5V (8500 mV)

Example alert: Battery c423 is over voltage at 8.5volts

Battery System Low Power

Creates an alert when the battery's power reaches 20% charge

Example alert: Battery system is at 20% charge with 60 minutes remaining

Battery System Power Off

Creates an alert when the battery's power reaches 7% charge

Example alert: Battery system is at 7% charge with 10 minutes remaining

Battery Maintenance Cycle Started

The battery automatically begins discharging then recharges to full power, for optimizing battery life. (E400/X20 devices)

Battery Maintenance Cycle Ended

The battery has finished its maintenance cycle. (E400/X20 devices)

Battery Backup Power Engaged

When an E400/X20 device loses wall power and switches over to battery backup.

Wall Power Restored

When an E400/X20 device regains wall power and switches back from battery backup mode.