The following information is required for ATEX (Europe) and CID2 (North America) hazardous location installations.
Hazardous Environment Information
Installation Instructions are provided with each device.
Tamb: -20°C to +60°C.
Temperature Code: T4.
Altitude up to 2000 m (or 80 kPa).
The device is not to be used with the included AC/Wall power adapter in hazardous locations.
DC Power Port: For 12V DC use 20 AWG wire for lengths up to 20 meters.
Electrical Ratings for Accessories:
Accessory
Input
Output
MC20-ETH Expansion Module
3.3V DC @ 103mA
N/A
MC20-SRL Expansion Module
3.3V DC @ 35mA
N/A
MC20-GPO Expansion Module
3.3V DC @ 50mA
N/A
5V DC @ 200mA
3.3V DC @ 200 mA
12V DC @ 100 mA
12V DC @ 100 mA
Electrical Ratings for Router:
Component
Input
DC Power Port
12V DC @ 1.5A
PoE
56V DC @ 0.23A
Hazardous Environment Considerations
The equipment shall be installed in an enclosure with a tool removable door or cover that provides a degree of protection not less than IP 54 in accordance with IEC/EN 60079-0 or equivalent.
Conditions of Use: ATEX
All ATEX certified equipment (including expansion modules MC20-ETH, MC20-SRL, MC20-GPO and the S400-C6-EA router) must adhere to the conditions of use. Follow all safety and installation instructions above, including electrostatic handling instructions, and the following conditions of use:
The equipment shall only be used in an area of not more than pollution degree 2, as defined in EN 60664-1.
The equipment shall be installed in an ultimate enclosure only accessible with the use of a tool and that provides a degree of protection not less than IP 54 in accordance with EN IEC 60079-0 and EN IEC 60079-7.
Transient protection shall be provided that is set at a level not exceeding 140% of the peak rated voltage value at the supply terminals to the equipment.
Conditions of Use: CID2
Installation Instructions are provided with each device and shall include the following in addition to ordinary locations marking under File E467298-A6020-UL, Issued 2022-10-20.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D OR non-hazardous locations only.
Warning
WARNING – EXPLOSION HAZARD. DO NOT DISCONNECT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS FREE OF IGNITIBLE CONCENTRATIONS.
This device is an open-type device to be installed in a tool-only accessible enclosure suitable for the environment.
Antennas intended for use in Class I, Division 2 Hazardous Locations must be installed within the end use enclosure.
Detailed Environment Specifications
For safety certification requirements, these specifications apply when installing the S400 series router:
Environmental | |
|---|---|
Temperature |
|
Humidity |
|
Ingress Protection | IP30 |
Certifications | |
|---|---|
Safety |
|
Materials |
|
Shock/Vibration/Humidity |
|
Hazardous Locations | North America: Class I, Division 2, Groups A, B, C, and D Europe - ATEX: UL 24 ATEX 3274X Held by: Ericsson Enterprise Solutions, Inc 1100 W. Idaho Street Suite 800 Boise, ID 83702-5389 United States |
Regulatory | FCC (U.S.) IC (Canada) CE (European Union) UKCA (UK) RCM (AU/NZ) ANATEL (Brazil) IFT (Mexico) SUBTEL (Chile) MCMC (Malaysia) IMDA (Singapore) |
Document Part Number: 500360-002
17 November 2024