Configuring for Vehicle Telemetry in NetCloud OS - OBDII/Configuring-for-Vehicle-Telemetry-in-NetCloud-OS

CAN Bus Vehicle Telemetry Guide and General Information

ft:locale
en-US
ft:sourceName
Paligo_Prod

The following steps outline how to configure the routers to interface with the selected adapter, collect PID status, and forward the OBD-II information in NMEA form to a client or server. The following steps assume the router and an LD3ICS-S are already installed in a vehicle.

  1. Log into Ericsson NetCloud Manager.

  2. Select Devices in the left-side navigation panel.

  3. Select a router from the Routers page. Alternatively, to make configuration changes to a group, navigate to the Groups page and select a group.

  4. Select Configuration and then Edit.

  5. Navigate to SYSTEM > Administration > Vehicle Telemetry.

  6. Check the Enable Vehicle Telemetry checkbox.

  7. Select the CAN Connection Module.

  8. Select Save.

  9. If you know which PIDs are supported by the vehicle, skip to the next step. If not, check the Supported field in the OBD-II and J1939 PID tables:

    1. Navigate to STATUS > Vehicle Telemetry.

      Note

      You must be in a remote connect session to the router to access the NCOS STATUS page.

    2. Confirm the vehicle is detected; vehicle detection is indicated by the VIN field being populated in the OBD-II Vehicle Readings table.

    3. If the vehicle is not detected, select Redetect Vehicle and wait up to 5 minutes.

    4. Confirm the adapter is configured by viewing the Adapter Configured field reading true in the OBD-II Adapter Status table.

    5. If the vehicle is detected and the adapter is configured, take note of Supported PIDs because only Supported PIDS should be enabled. An enabled, unsupported PID will return a null value in the OBD-II NMEA sentence.

    6. Return to SYSTEM > Administration > Vehicle Telemetry to begin enabling and configuring PIDs.

  10. Enable and Configure Update Interval for desired PIDs:

    1. Select the PID and select Edit.

    2. Select the Enable box and configure the Update Interval.

      Note

      The vehicle's OBD-II interface only update a maximum of 20 PIDs per second, so when many PIDs are enabled, the update interval will need to be adjusted accordingly. The Update Interval must be in increments of 50 ms; if configured to a smaller interval, the router will automatically round to the nearest increment.

  11. Enable OBD-II data to be sent with GPS: Check the box labeled Send OBD-II Data with GPS and press Save.

  12. Configure GPS and/or OBD-II NMEA sentences:

    1. Navigate to SYSTEM > Administration > GPS.

    2. Confirm GPS is enabled. If not, enable it and then select Save button.

      Note

      OBD-II reporting requires GPS to be enabled.

    3. Configure the desired recipient of the NMEA Sentences by configuring Send to Client(s) or Send to Server(s).

    4. After entering the Send to Client(s) or Send to Server(s) details, choose NMEA as the Language on page 2 of the pop-up.

  13. Select whether and what other GPS information you want sent.

  14. Configure the Reporting Interval as needed.